Steam Point Boilers & Heaters Pvt. Ltd.
None

Call us: +918889011101

Oil & Gas Fired Hot Air Generator

Oil & Gas Fired Hot Air Generator

500000.00 - 2000000.00 INR/Unit

Product Details:

X

Oil & Gas Fired Hot Air Generator Price And Quantity

  • 1 Unit
  • 500000.00 - 2000000.00 INR/Unit

Oil & Gas Fired Hot Air Generator Trade Information

  • 10 Unit Per Month
  • 4-6 Week

Product Description

We are counted amongst as the foremost and most reliable manufacturers, exporters and suppliers of an extensive range of Gas Fired Hot Air Generator. The offered generator is specifically designed for broad industrial applications for the process of heating and cleaning the warm air under the most suitable temperature. The provided generator is manufactured using high grade components and cutting edge technology under the strict guidance of our professionals. Apart from this, our valuable clients can avail the offered Gas Fired Hot Air Generator in various specifications at industry leading prices from us.

Features:

·         Hassle-free operation

·         High performance

·         Ergonomic design

·         Low maintenance


The "THERMOTECH" AIR SYSTEM essentially comprises of a fully automatic multi pass counter current. Hot Air Generators that consists of stainless steel shell type integral combustion chamber and is accommodated in multi M.S. Shell. The cold air is inserted by a suitable capacity blower fan in first pass, absorbs heat from fuel gas passage and accordingly both hot fuel gas and cold air travel in opposite direction in passage,

Which ultimately transfers the 90% heat to cold air and delivers hot air from hot air outlet. The system functions fully automatic on temperature sensing element, fixed on hot air output, which starts or shuts off the burner at pre set temperature. The system is package type, fixed on a common base frame and available in different range from 1 lac kcal/hr. to 10 lacs kcal/hr.

BLOWER FAN

A centrifugal blower fan coupled with suitable motor of suitable capacity is coupled with inlet of hot air generator which push the required quantity of fresh air.

BURNER

An imported single or two stage light oil monoblock burner with duplex filter mounted on hot air generator for smooth working.

AUTO CONTROLS / SAFETY

Hot Air Temperature Controller

The digital temperature indicator cum controller cut off the burner at preset hot air temperature.

Stack Temperature Controller

The Blind temperature controller cut off the burner at high stack temperature to prevent in case of cold air inlet blower failure to safe guard radiation chamber.

Flame Failure

Photocell actuated audio visual alarm and automatic cut off.

Burner Interlock

The burner is electrically interlocking, which allows burner to fire only after start of cold air blower fan.

TYPICAL APPLICATION

·         Units in higher capacity 10,00,000 kcal/hr and above available on request.

·         Units with higher outlet air temperature also available on request.

·         Units can be supplied to suit tailor made air flows and outlet pressure.

·         Fuel consumption based on GCV of LDO-10700 & FO-10200.

·         Chemical/Dyestuff Industries.

·         Salt Drying Industries.

·         Laundry.

·         Paints-oven heating.

·         Textile.

·         Spray Dryer.

·         Spin fresh dryer.

Technical Specification:

 

Details

Units

HAG 10

HAG 20

HAG 30

HAG 40

HAG 50

Rated heat output

Kcal/hr

100000

200000

300000

400000

600000

Maximum Air Pump

C


200

Outlet Air Pressure

Mm of WG


100

Approx Hot Air Available at 200C

CFM

1125

2250

3370

4470

6750

M/hr

1910

3815

5725

7585

11450

Overall Thermal Efficiency on GCV

%

86+-1

Rated Fuel Consumption

LDO

Kg/hr

10.70

21.5

32.2

43.0

64.3

FO



33.8

45.0

67.6

Burner control


ON/OFF

High / Low

Electric Supply


415 + 5% 50Hz3ph 4 wire

Main Air Blower motor

kw

2.25

3.75

5.00

7.5

11.25

Burner Motor

0.5

0.5

0.75

0.75

1.5

Fuel oil preheter (for operation on F.O)

-

-

3.0

6.0

6.0

Total connected electrical load

LDO

kw

2.75

4.25

5.75

8.25

12.75

FO

-

-

8.75

11.25

18.75

Overall Dimensions

Height

mm

1500

2000

2200

2500

2800

Length

2500

3000

3500

4000

5000

Width

1100

1500

1500

1800

2500

Dry Weight

kgs

1200

2000

2800

3500

5300

  • Unit in higher capacity 1000000 kcal/hr and above available on request
  • Units with higher outlet air temperature also available on request.
  • Units can be supplied to suit tailor made air flows and outlet pressure.
  • Fuel consumption based on GCV of LDO-10700 & FO-10200
Enter Buying Requirement Details
Email Id
Mobile number

Other Products in 'Oil Gas Fired Thermic Fluid Heater ' category



"We are mainly dealing in Madhya Pradesh."